USAfixTM - Repair Guide (RG) - Master Email RG
- Check for Power to the Vac Motor
 Level of Difficulty - HIGH  Estimated Completion Time - 15 minutes
TASKI - SWINGO 750B

Tools Required
Tool 
Screwdriver-flat tip
Screwdriver-phillips
Torx T30
Volt meter (True RMS capable)

Parts Required
PartDescriptionPriceAvailablePurchase
192-0770 24V 2 stage vacuum motor $257.63 Back Order Qty:


Step Procedure & Parts & Tools
1 RAISE THE TANK COVER

2 PROP THE TANK WITH THE PROP ROD

3 PULL THE FLOAT TO REMOVE IT FROM THE INSIDE COVER

4 USING A TORX WRENCH, REMOVE THE 3 SCREWS HOLDING THE FILTER TO THE INSIDE COVER
Torx T30

5 PULL TO REMOVE THE FILTER FROM THE INSIDE COVER

6 USING A TORX WRENCH, REMOVE THE 3 SCREWS HOLDING THE INSIDE COVER NOTE: YOU WILL NEED TO PROP THE COVER BECAUSE ONE OF THE SCREWS BEING REMOVED HOLDS THE PROP ROD
Torx T30

7 PULL THE INSIDE COVER TO REMOVE IT

8 DISCONNECT THE WHITE CONNECTOR PLUG INSERT PROBES INTO THE CONNECTOR PLUG. RED PROBE TO RED WIRE AND BLACK PROBE TO BLACK WIRE. TURN UNIT ON. TURN VAC MOTOR ON. CHECK READING ON VOLT METER. VOLT METER SHOULD READ 24 VOLTS.
Volt meter (True RMS capable)